Air Conditioner - Condensation or moisture dripping from indoor unit
Issue
Condensation or moisture dripping from indoor unit
Applies to
- Westinghouse Split System Air Conditioner
- Kelvinator Split System Air Conditioner
Solution
Do not operate the air conditioner for long periods with the airflow direction set
downward in cool or dry mode. Otherwise, condensation may occur on the surface of the horizontal louver causing moisture to drop onto the floor or on furnishings.
If the air conditioner runs for a long time in cooling mode and the humidity is high, condensed water may drip out of the unit. Set the vertical airflow louver to its maximum angle (vertically to the floor) and set HIGH fan mode.
To set the vertical air flow (up-Down) direction
- Perform this function while the unit is in operation. Use the remote controller to adjust the air-flow direction. The horizontal louver can swing up and down automatically.
Important
Do not put your fingers into the panel of blower and suction side. The high-speed fan may cause danger.
- Open angle of the horizontal louver should not be set too small, as COOLING or HEATING performance may be impaired due to too restricted air flow area.
- Do not move the horizontal louver manually, otherwise the horizontal louver will be out of sync. Please cease operating, unplug power for a few seconds, then restart the air conditioner.
- Do not operate unit with horizontal louver in closed position.
Was this article helpful?
Related Articles
- Air Conditioner | How to clean and maintain your air conditioner
- Air Conditioner - water not draining
- Air-Conditioner - Window Wall not heating
- Air Conditioner - Indoor unit displays DF and heating operation stops
- Air Conditioner - louver not closing properly
- Air Conditioner - Window Wall, water not draining
- Air Conditioner - Window Wall, Control Panel Display not working, Display lights are off
- Air Conditioner - Emits Hissing, Squeaking, Rushing Air sounds
- Air conditioner | How to set up Advanced features
- Air Conditioner - Displays Error Code E(x), P(x), F(x) EH(xx), EL(xx), EC(xx) PH(xx), PL(xx), PC(xx)
In Warranty Service & Repair
Need to arrange a repair technician visit? Repairs under warranty are free of charge and we are here to support you after your warranty has expired. Authorised Technicians and genuine parts for complete peace of mind.
Related Articles
- Air Conditioner | How to clean and maintain your air conditioner
- Air Conditioner - water not draining
- Air-Conditioner - Window Wall not heating
- Air Conditioner - Indoor unit displays DF and heating operation stops
- Air Conditioner - louver not closing properly
- Air Conditioner - Window Wall, water not draining
- Air Conditioner - Window Wall, Control Panel Display not working, Display lights are off
- Air Conditioner - Emits Hissing, Squeaking, Rushing Air sounds
- Air conditioner | How to set up Advanced features
- Air Conditioner - Displays Error Code E(x), P(x), F(x) EH(xx), EL(xx), EC(xx) PH(xx), PL(xx), PC(xx)